A New Approach To Pressure-Sensitive Palatography Using A Capacitive Sensing Device

Number 1312
Year 2003
Drawer 25
Entry Date 01/16/2008
Authors Mark Tiede, Joseph Perkell, Majid Zandipour, Melanie Matthies and Ellen Stockmann
Contact
Publication Proceedings of the 15th International Congress of Phonetic Sciences. Barcelona, Spain. August 3-9, 2003. Universitat Autònoma de Barcelona, pp.3149-3152
url http://www.haskins.yale.edu/Reprints/HL1312.pdf
Abstract In this work we report on a new type of pressure sensor and its application to palatography. The device is a flexible sheet sensitive to pressure-induced changes in capacitance with a spatial resolution of 2 mm. When mounted to a plastic palatal plate thermoformed off a subject’s dental cast we have used it to record lingual palatall contact pressure from 25 distributed locations at a 40Hz/sensor sampling rate. Because of pervasive noise and problems with calibration our results obtained using the device are preliminary, though consistent with previous work in this area.
Notes